--MibName=rosMgmtAlarm
-- *****************************************************************
-- ROSMGMT-ALARM-MGMT-MIB.mib:  ROSMGMT ALARM MIB
--
-- April 2011, yangguodong
--
-- Copyright (c) 1996-2011 by Raisecom Technology Co., Ltd. 
-- All rights reserved.
-- 
-- *****************************************************************
--

  ROSMGMT-ALARM-MGMT-MIB DEFINITIONS ::= BEGIN

  IMPORTS
     MODULE-IDENTITY,OBJECT-TYPE,
     Unsigned32,Integer32
        FROM SNMPv2-SMI                 -- [RFC2578]
     TEXTUAL-CONVENTION,TruthValue
        FROM SNMPv2-TC                     -- [RFC2579]   

     SnmpAdminString
       FROM SNMP-FRAMEWORK-MIB         -- [RFC3411]       
     ifIndex             FROM IF-MIB   
     rosMgmt
				FROM RAISECOM-BASE-MIB;
 
  rosMgmtAlarmMgmt MODULE-IDENTITY
     LAST-UPDATED "202006180000Z"  -- 18 June 2020 00:00:00 GMT
     ORGANIZATION "Raisecom Technology Co., Ltd."
     CONTACT-INFO
        "Raisecom Science & Technology Co., ltd.
        E-mail: support@rosMgmt.com ."	 
     DESCRIPTION
        "This MIB module contains managed object definitions for
         MPLS. "
	 REVISION   "202006180000Z"  -- 18 June 2020 00:00:00 GMT
	 DESCRIPTION
	"Add alarm reversal mode to automatically flip state."
	 REVISION   "201103120000Z"  -- 12 March 2011 00:00:00 GMT
	 DESCRIPTION
	"ROSMGMT ALARM MIB initial version."
        ::= { rosMgmt 34 }
	--rosMgmtAlarmMgmt 0 notification
	rosMgmtAlarmMgmtObejcts OBJECT IDENTIFIER ::= { rosMgmtAlarmMgmt 1 } 
	--rosMgmtAlarmMgmt 2 conformance group
    -- User-defined types  
	AlarmStorageMode ::= TEXTUAL-CONVENTION
	   STATUS       current
	   DESCRIPTION
	            "Describes how to store alarm active table when the alarm
	            table was full.When the storage mode is stop,the new raised
	            alarm will be discarded.It will not insert to alarm active table.
	            If the storage mode is loop,the oldest row in alarm active table
	            will be deleted and the the newly raiseco alarm will be inserted 
	            to the alarm active table."
	            
	   SYNTAX       INTEGER {
	                     stop(1),       -- eh?
	                     loop(2)    -- e.g., in RAM
	                   } 

	AlarmInverseMode ::= TEXTUAL-CONVENTION
	   STATUS       current
	   DESCRIPTION
	            "Describes the mode of alarm inverse "
	            
	   SYNTAX       INTEGER {
	                     none(1),       -- inverse mode is non
	                     auto(2),       -- inverse mode is auto
	                     manual(3),      -- inverse mode is manual 
			             autofinish(4)      -- inverse mode is auto finish
	                   }  	                     
	--end user defined type                   

	--start of alarm config  
	rosMgmtAlarmMgmtScalarGroup OBJECT IDENTIFIER ::= { rosMgmtAlarmMgmtObejcts 1 }
	rosMgmtAlarmMgmtRaiseDelay OBJECT-TYPE
	SYNTAX            Integer32 (0..600) 
    UNITS             "seconds"	
	MAX-ACCESS        read-write
	STATUS            current 
	DESCRIPTION
	   "The approximate period from the time a alarm was 
	   raised to a time this alarm was reported."   
	DEFVAL { 0 }
	::= { rosMgmtAlarmMgmtScalarGroup 1}  
	
	rosMgmtAlarmMgmtClearDelay OBJECT-TYPE
	SYNTAX            Integer32  (0..600) 
    UNITS             "seconds"	
	MAX-ACCESS        read-write
	STATUS            current 
	DESCRIPTION
	   "The approximate period from the time a alarm was 
	   cleared to a time this alarm report."   
	DEFVAL { 0 }
	::= { rosMgmtAlarmMgmtScalarGroup 2 }    
	
	rosMgmtAlarmMgmtActiveStoreMode OBJECT-TYPE
	SYNTAX            AlarmStorageMode 
	MAX-ACCESS        read-write
	STATUS            current 
	DESCRIPTION
	   "The storage mode of the alarm active table"   
	::= { rosMgmtAlarmMgmtScalarGroup 3 }   
	
	rosMgmtAlarmMgmtInhibitEnable OBJECT-TYPE
	SYNTAX            TruthValue 
	MAX-ACCESS        read-write
	STATUS            current 
	DESCRIPTION
	   "Enable or Disable Alarm Inhibit"   
	DEFVAL { true }   
	::= { rosMgmtAlarmMgmtScalarGroup 4 }    
	
	rosMgmtAlarmMgmtSyslogEnable OBJECT-TYPE
	SYNTAX            TruthValue 
	MAX-ACCESS        read-write
	STATUS            current 
	DESCRIPTION
	   "Enable or Disable write syslog when an alarm raise"   
	DEFVAL { true }   
	::= { rosMgmtAlarmMgmtScalarGroup 5 }  
	
	rosMgmtAlarmMgmtActiveClear OBJECT-TYPE
	SYNTAX            Integer32  
	MAX-ACCESS        read-write
	STATUS            current 
	DESCRIPTION
	   "clear active alarm according to the active table third index"   
	::= { rosMgmtAlarmMgmtScalarGroup 6 }	
	
	
	rosMgmtAlarmMgmtConfigTable   OBJECT-TYPE 
     SYNTAX        SEQUENCE OF RosMgmtAlarmMgmtConfigEntry
     MAX-ACCESS    not-accessible
     STATUS        current
     DESCRIPTION
         "This table specifies the information of alarm configuration."
     ::= { rosMgmtAlarmMgmtObejcts 2 }
     
	rosMgmtAlarmMgmtConfigEntry   OBJECT-TYPE
     SYNTAX        RosMgmtAlarmMgmtConfigEntry
     MAX-ACCESS    not-accessible
     STATUS        current
     DESCRIPTION
          "A row in this table represents the configuration of specified alarm."
     INDEX  { rosMgmtAlarmMgmtId,ifIndex }
            ::= { rosMgmtAlarmMgmtConfigTable 1 }
            
	RosMgmtAlarmMgmtConfigEntry ::= SEQUENCE {
        rosMgmtAlarmMgmtId            Unsigned32,
        rosMgmtAlarmMgmtClear         TruthValue,
        rosMgmtAlarmMgmtReportEnable  TruthValue, 
        rosMgmtAlarmMgmtMonitorEnable TruthValue,
        rosMgmtAlarmMgmtInverseMode   AlarmInverseMode,  
        rosMgmtAlarmMgmtModuleName    SnmpAdminString,
        rosMgmtAlarmMgmtGroupName     SnmpAdminString
        }  
        
	rosMgmtAlarmMgmtId OBJECT-TYPE
	SYNTAX        Unsigned32
	MAX-ACCESS    not-accessible
	STATUS        current
	DESCRIPTION
         "First index of alarm config table which is equal to alarm group Id"
     ::= { rosMgmtAlarmMgmtConfigEntry 1 }   
     
 	rosMgmtAlarmMgmtClear OBJECT-TYPE
	SYNTAX        TruthValue
	MAX-ACCESS    read-write
	STATUS        current
	DESCRIPTION
         "The swith of alarm clear,when open the swith the related
         active alarm entry will be deleted from alarm active table" 
    DEFVAL { false }
     ::= { rosMgmtAlarmMgmtConfigEntry 2 }   
     
  	rosMgmtAlarmMgmtReportEnable OBJECT-TYPE
	SYNTAX        TruthValue
	MAX-ACCESS    read-write
	STATUS        current
	DESCRIPTION
         "Enable or disable Alarm Report" 
    DEFVAL { true }
     ::= { rosMgmtAlarmMgmtConfigEntry 3 }
  
  	rosMgmtAlarmMgmtMonitorEnable OBJECT-TYPE
	SYNTAX        TruthValue
	MAX-ACCESS    read-write
	STATUS        current
	DESCRIPTION
         "Enable or disable alarm monitor" 
    DEFVAL { true }
     ::= { rosMgmtAlarmMgmtConfigEntry 4 } 
     
  	rosMgmtAlarmMgmtInverseMode OBJECT-TYPE
	SYNTAX        AlarmInverseMode
	MAX-ACCESS    read-write
	STATUS        current
	DESCRIPTION
         "The mode of alarm inverse" 
    DEFVAL { none }
     ::= { rosMgmtAlarmMgmtConfigEntry 5 }  
      
    rosMgmtAlarmMgmtModuleName OBJECT-TYPE
    SYNTAX     SnmpAdminString (SIZE(0..32))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The module name which this alarm belongs to."
    ::= { rosMgmtAlarmMgmtConfigEntry 6 } 
    
    rosMgmtAlarmMgmtGroupName OBJECT-TYPE
    SYNTAX     SnmpAdminString (SIZE(0..32))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The name of alarm group."
    ::= { rosMgmtAlarmMgmtConfigEntry 7 }   
 
 rosMgmtAlarmMgmtCfgTable     OBJECT-TYPE 
     SYNTAX        SEQUENCE OF RosMgmtAlarmMgmtCfgEntry 
     MAX-ACCESS    not-accessible
     STATUS        current
     DESCRIPTION
         "This table specifies the information of alarm configuration."
     ::= { rosMgmtAlarmMgmtObejcts 3 }
     
  rosMgmtAlarmMgmtCfgEntry   OBJECT-TYPE
     SYNTAX        RosMgmtAlarmMgmtCfgEntry 
     MAX-ACCESS    not-accessible
     STATUS        current
     DESCRIPTION
          "A row in this table represents the configuration of specified alarm."
     INDEX  { rosMgmtAlarmMgmtCfgAlarmType,rosMgmtAlarmMgmtCfgAlarmResType,rosMgmtAlarmMgmtCfgAlarmRes}
            ::= { rosMgmtAlarmMgmtCfgTable 1 }
            
	RosMgmtAlarmMgmtCfgEntry ::= SEQUENCE { 
	    rosMgmtAlarmMgmtCfgAlarmType     Unsigned32,
        rosMgmtAlarmMgmtCfgAlarmResType  INTEGER,
        rosMgmtAlarmMgmtCfgAlarmRes      Unsigned32,
        rosMgmtAlarmMgmtCfgClear         TruthValue,
        rosMgmtAlarmMgmtCfgMonitorEnable  TruthValue,
        rosMgmtAlarmMgmtCfgReportEnable  TruthValue,
        rosMgmtAlarmMgmtCfgInverseMode   AlarmInverseMode 
        }  
                                 
 	rosMgmtAlarmMgmtCfgAlarmType OBJECT-TYPE
	SYNTAX        Unsigned32
	MAX-ACCESS    not-accessible
	STATUS        current
	DESCRIPTION
         "Third index of alarm Mgmt config table.The type of Alarm."
     ::= { rosMgmtAlarmMgmtCfgEntry 1 }  
            
	rosMgmtAlarmMgmtCfgAlarmResType OBJECT-TYPE
	SYNTAX INTEGER {
					slotindex(1),	--澯Դ:忨
					pwindex(2),	--澯ԴPW
					lspindex(3),	--澯ԴLSP
					loifindex(4),	--澯ԴLOOPBACK 
					agifindex(5),	--澯ԴAG
					apifindex(6),	--澯ԴAP
					obifindex(7),	  --澯ԴOUTBAND  
					tdmifindex(8),	--澯ԴTDM  
					tunnelifindex(9),	--澯ԴTRUNK
					vlanifindex(10),	--澯ԴVLAN   
					subifindex(11),	--澯ԴSUBIF 
					portindex(12),	--澯Դ˿
					apagsubifindex(13),	--澯ԴAP,AG,ӽӿ
					powerindex(14), --澯ԴԴ
					fanindex(15),	--澯Դ
					boardindex(16),	--澯Դ忨Դ
					cfmindex(17),	
					erpsindex(18),	
					apsindex(19),	
					bfdindex(20),	
					ldpindex(21),
					lsaindex(22),
					ifindex(23),
					cpuindex(24),
					tdmsubifindex(25),
					tdmtdmsubifindex(26),
					stmifindex(27),
					stmsubifindex(28),
					stmsubtdmtdmsubindex(29),
					stmvcindex(30),
					eponifindex(31),
					eonuifindex(32),
					eonusubifindex(33),
					apeponifindex(34),
					apagvlansubifindex(35)
		        } 
	MAX-ACCESS    not-accessible
	STATUS        current
	DESCRIPTION
         "First index of alarm Mgmt config table.The type of Alarm Resoure."
     ::= { rosMgmtAlarmMgmtCfgEntry 2 }  
     
	rosMgmtAlarmMgmtCfgAlarmRes OBJECT-TYPE
	SYNTAX        Unsigned32
	MAX-ACCESS    not-accessible
	STATUS        current
	DESCRIPTION
         "Second index of alarm Mgmt config table.The value of Alarm Resoure."
     ::= { rosMgmtAlarmMgmtCfgEntry 3 } 
                
  rosMgmtAlarmMgmtCfgClear OBJECT-TYPE
	SYNTAX        TruthValue
	MAX-ACCESS    read-write
	STATUS        current
	DESCRIPTION
         "The swith of alarm clear,when open the swith, the related active alarm entry will be deleted from alarm active table." 
    DEFVAL { false }
     ::= { rosMgmtAlarmMgmtCfgEntry 4 } 
     
  rosMgmtAlarmMgmtCfgMonitorEnable OBJECT-TYPE
	SYNTAX        TruthValue
	MAX-ACCESS    read-write
	STATUS        current
	DESCRIPTION
         "Enable or disable alarm Monitor." 
    DEFVAL { true }
     ::= { rosMgmtAlarmMgmtCfgEntry 5 }   
     
  rosMgmtAlarmMgmtCfgReportEnable  OBJECT-TYPE
	SYNTAX        TruthValue
	MAX-ACCESS    read-write
	STATUS        current
	DESCRIPTION
         "Enable or disable alarm Report." 
    DEFVAL { true }
     ::= { rosMgmtAlarmMgmtCfgEntry 6 }    
     
  rosMgmtAlarmMgmtCfgInverseMode  OBJECT-TYPE
	SYNTAX        AlarmInverseMode
	MAX-ACCESS    read-write
	STATUS        current
	DESCRIPTION
         "Alarm Inverse Mode." 
    DEFVAL { none }
     ::= { rosMgmtAlarmMgmtCfgEntry 7 }      
     
    --end of alarm config  

	rosMgmtAlarmMgmtMonitorLevel OBJECT-TYPE
	SYNTAX            INTEGER {
					clear(1),
					indeterminate(2),
					critical(3),     
					major(4),        
					minor(5),        
					warning(6)
	                         }
	MAX-ACCESS        read-write
	STATUS            current 
	DESCRIPTION
	   "The level of Alarm Monitor."   
	DEFVAL { minor }
	::= { rosMgmtAlarmMgmtScalarGroup 7} 
	 
	rosMgmtAlarmMgmtClearLevel OBJECT-TYPE
	SYNTAX            INTEGER {
								clear(1),
								indeterminate(2),
								critical(3),     
								major(4),        
								minor(5),        
								warning(6)
	                   }
	MAX-ACCESS        read-write
	STATUS            current 
	DESCRIPTION
	   "The level of Alarm Monitor."   
		::= { rosMgmtAlarmMgmtScalarGroup 8}  	 
	
	rosMgmtAlarmMgmtMonitor OBJECT-TYPE
	SYNTAX        TruthValue
	MAX-ACCESS    read-write
	STATUS        current
	DESCRIPTION
         "Enable or Disable Alarm Monitor." 
    DEFVAL { true }
     ::= { rosMgmtAlarmMgmtScalarGroup 9 } 
     
     
  rosMgmtAlarmMgmtCorrelationInhibit OBJECT-TYPE
	SYNTAX        TruthValue
	MAX-ACCESS    read-write
	STATUS        current
	DESCRIPTION
         "Enable or Disable Alarm CorrelationInhibit." 
    DEFVAL { true }
     ::= { rosMgmtAlarmMgmtScalarGroup 10 }  
     
  rosMgmtAlarmMgmtReport OBJECT-TYPE
	SYNTAX        TruthValue
	MAX-ACCESS    read-write
	STATUS        current
	DESCRIPTION
         "Enable or Disable Alarm Report." 
    DEFVAL { true }
     ::= { rosMgmtAlarmMgmtScalarGroup 11 }      
  
-- rosMgmtAlarmMgmtCfgOutPutTable     OBJECT-TYPE 
--     SYNTAX        SEQUENCE OF RaisecomAlarmMgmtCfgOutPutEntry 
--     MAX-ACCESS    not-accessible
--     STATUS        current
--     DESCRIPTION
--         "This table specifies the information of alarm configuration."
--     ::= { rosMgmtAlarmMgmtObejcts 14 }
--     
--  rosMgmtAlarmMgmtCfgOutPutEntry   OBJECT-TYPE
--     SYNTAX        RaisecomAlarmMgmtCfgOutPutEntry 
--     MAX-ACCESS    not-accessible
--     STATUS        current
--     DESCRIPTION
--          "A row in this table represents the configuration of specified alarm."
--     INDEX  { rosMgmtAlarmMgmtAlarmOutputGroupIndex, rosMgmtAlarmMgmtAlarmOutputType}
--     ::= { rosMgmtAlarmMgmtCfgOutPutTable 1 }
--            
--	RaisecomAlarmMgmtCfgOutPutEntry ::= SEQUENCE { 
--        rosMgmtAlarmMgmtAlarmOutputGroupIndex   INTEGER, 
--        rosMgmtAlarmMgmtAlarmOutputType         Unsigned32, 
--        rosMgmtAlarmMgmtAlarmOutputRowStatus    TruthValue      
--        }  
--                                 
--  rosMgmtAlarmMgmtAlarmOutputGroupIndex OBJECT-TYPE
--	SYNTAX            INTEGER (1..2)
--	MAX-ACCESS        not-accessible
--	STATUS            current 
--	DESCRIPTION
--	   "The index of alarm Mgmt OutputGroup table."   
--	::= { rosMgmtAlarmMgmtCfgOutPutEntry 1}   
--
-- rosMgmtAlarmMgmtAlarmOutputType OBJECT-TYPE
--	SYNTAX        Unsigned32
--	MAX-ACCESS    not-accessible
--	STATUS        current
--	DESCRIPTION
--         "Third index of alarm Mgmt config table.The type of Alarm."
--     ::= { rosMgmtAlarmMgmtCfgOutPutEntry 2 }  
--	
--  rosMgmtAlarmMgmtAlarmOutputRowStatus OBJECT-TYPE
--	SYNTAX        TruthValue						
--	MAX-ACCESS    read-write
--	STATUS        current
--	DESCRIPTION
--         "Enable or disable Alarm Output"  
--    DEFVAL { true }                
--	::= { rosMgmtAlarmMgmtCfgOutPutEntry 3} 	
--
--
-- rosMgmtAlarmMgmtCfgOutPutGroupTable     OBJECT-TYPE 
--     SYNTAX        SEQUENCE OF RaisecomAlarmMgmtCfgOutPutGroupEntry 
--     MAX-ACCESS    not-accessible
--     STATUS        current
--     DESCRIPTION
--         "This table specifies the information of alarm configuration."
--     ::= { rosMgmtAlarmMgmtObejcts 15 }
--     
--  rosMgmtAlarmMgmtCfgOutPutGroupEntry   OBJECT-TYPE
--     SYNTAX        RaisecomAlarmMgmtCfgOutPutGroupEntry 
--     MAX-ACCESS    not-accessible
--     STATUS        current
--     DESCRIPTION
--          "A row in this table represents the configuration of specified alarm."
--     INDEX  { rosMgmtAlarmMgmtAlarmOutputgrpIndex}
--     ::= { rosMgmtAlarmMgmtCfgOutPutGroupTable 1 }
--            
--	RaisecomAlarmMgmtCfgOutPutGroupEntry ::= SEQUENCE { 
--        rosMgmtAlarmMgmtAlarmOutputgrpIndex   INTEGER, 
--        rosMgmtAlarmMgmtAlarmOutputEnable     EnableVar  
--        }  
--                                 
--    rosMgmtAlarmMgmtAlarmOutputgrpIndex OBJECT-TYPE
--	SYNTAX            INTEGER (1..2)
--	MAX-ACCESS        not-accessible
--	STATUS            current 
--	DESCRIPTION
--	   "The index of alarm Mgmt OutputGroup table."   
--	::= { rosMgmtAlarmMgmtCfgOutPutGroupEntry 1}   
--
-- 	rosMgmtAlarmMgmtAlarmOutputEnable OBJECT-TYPE
--	SYNTAX        EnableVar
--	MAX-ACCESS    read-write
--	STATUS        current
--	DESCRIPTION
--         "Third index of alarm Mgmt config table.The type of Alarm."
--     ::= { rosMgmtAlarmMgmtCfgOutPutGroupEntry 2 }  
	
                      
  END
